Our watch is in daily use, if it stops, don't be nervous, the watch stop is not necessarily bad. Did the watch accidentally appear a lockout? As soon as the watch is back to normal, you can leave it alone. Because of some random factors, the watch will also be stopped: during the use of the shock to make the hair hang; Forget to push the handle head after the pin. When a part is stuck, it will cause a stop, but then it can return to normal in time. This does not belong to the watch fault, mainly in the following situations:
1. Automatic mechanical watch lockout: increase the number of arms oscillations
 
"The new watch is worn for ten days" is not a performance issue, or it stops every day. Most likely, it was not enough to wear a watch, and the arms were so low that the watch didn't have enough momentum.
Sitting in today's society, people work more, drive the car, the pacers, less bent hands fill (string) has become a must be equipped with automatic watch, otherwise it will lead to mechanical watch when the length is not enough, often stop watch and accuracy variation as well. To know the automatic mechanical watch it is not the absolute "automatic" that everyone imagines and understands. So, the automatic mechanical watch is not as good as calling it "arm swing", which is probably more appropriate.
Processing method: automatic mechanical watch has a set of automatic winding mechanism, which can be used to string the machine with arms. In addition to individual Japanese watches, automatic mechanical watches can be used by hand, and the strings are used to compensate for the lack of automatic upper strings, or the lack of physical activity.
2. Partial vibration: rolling round internal pile adjustment
 
Severe "partial earthquakes" can also cause mechanical watch to stop. When the mechanical watch is shocked, it can lead to the loss of the disc. The nail is usually fixed in the corresponding hole of the double disk with the shellac. In fact, the reason for the mechanical watch shutdown is more than the fault of the wheel - wheel system, but the special fault of the cyclo-rotation system can cause the mechanical watch to stop completely. When the phenomenon of partial shock is severe, the mechanical watch may not be able to go up to stop the pendulum.
 
The solution: no flow outside the ring structure of the mechanical watch, will together with the balance wheel balance spring will clamp down and together with a small screwdriver, stretched out in the balance spring pile elastic groove, rolling circle pile to adjust.
The center of the disc is not in the center of the center of the swing axis and the center of the spindle axis. Once the disc nail is off, it can't add energy to the cyclostrating system, and the mechanical watch stops after the spring rebounces.
Processing method: when adjusting, pay attention to the direction of rolling, Angle and other related topics. It can reduce the gap of insurance by adjusting the limit nail, making it smaller than the total lock value.
3. Anti-pendulum phenomenon: it may be released on its own
 
The tip of the gear tooth slip to the cross - thrust surface, resulting in the impact, turning the fork to another limit nail. When the pendulum comes in, the disc is placed on the outside of the horn, which is the reverse pendulum, and the mechanical watch stops completely when the pendulum swings.
Inverse pendulum phenomenon is one of the failure cause mechanical watch completely stopped walking, big Yu Quansuo insurance clearance value or fork head nails too short, to the outside world, under transient impact interference escapement entering the bell mouth, at the end of the disc screw also may justify itself.
Processing method: if the length of the fork head is short, adjust the cross head nail or replace the appropriate escapement fork component to hit the deflection, and can adjust the external pile ring.
4. Magnetization: iron is the rescue method
 
In available such as contact has a strong magnetic field generator and motor objects, or accidentally put mechanical watch near the radio and TV, mechanical watch will be generators, motors, magnetization of the magnetic field of radio and TV. After the mechanical watch is magnetized, not only is it not accurate, some even stop.
 
Processing method: it is better to send the clock repair department to demagnetize, because there is a special equipment for demagnetization. If away from the watch shop repair is not convenient, can find a middle circle shape, be free from magnetic iron, vertical on the table, mechanical watches from iron slowly wear to wear to a circle, mechanical watch on the magnetic will be iron absorption.
 
Tips: the watch is a precision valuables, so as to avoid being deceived in the maintenance of the watch, or cause the watch to be irreparable, if you need to repair the service, please accept the normal after-sale center for repairs.
 